GE LOGIQ E9 XDclear 2.0 Ultrasound Machine

ge voluson p8 ultrasound machine

The GE Logiq E9 with XDclear 2.0 is the GE’s full featured premium product for general purpose diagnostic ultrasound and helps you quickly acquire the information you need, in both routine and difficult procedures, to guide decisions that enhance clinical confidence.

Applications: Abdominal, Small parts and superficial, Pediatric, Musculoskeletal, Intraoperative, Urology, Prostate, Obstetrical, Gynecological, Fertility, Breast, Vascular, Transcranial Doppler, Cardiac, Pediatrics, Liver, Interventional, Strain/Shearwave Elastography, Stress echo, Radiology

 

pdf icon small GE LOGIQ E9 XDclear 2.0 Ultrasound Imaging Brochure

pdf icon small GE LOGIQ E9 XDclear 2.0 Ultrasound Vascular Imaging Brochure

pdf icon small GE LOGIQ E9 XDclear 2.0 Ultrasound Transducer Guide

 

GE LOGIQ E9 with XDclear 2.0 Features:
• 23” Wide screen High-Resolution LCD LED backlit display
• 22” Wide screen High-Resolution OLED Display
• Monitor translation: 350mm, 13.7 in. horizontal; 120mm, 4.7 in. vertical; 90 degree swivel
• Advanced user interface with high resolution 10.4 inch touch screen
• Integrated Hard Disk Drive (500 GB)
• Integrated DVD-R Multi Drive
• 4 Active Probe Ports
• KBD/Monitor up-down mechanism (200mm adjustable in height)
• On-board storage for peripherals: Black/white printer.
• Rear Storage Cover for Peripheral Connectors and Cables
• Probe Holder, removable for cleaning and washing
• Gel Holder, removable for cleaning and washing
• Integrated Gel Warmer (option)
• Integrated speakers with sub-woofer for premium sound
• Wheels. Wheel diameter: 175mm. Rotating flexible wheels with protective cover. Locking Mechanism for wheels.
• Automatic Optimization
• CrossXBeam
• Speckle Reduction Imaging (SRI-HD)
• Fine Angle Steer
• Coded Harmonic Imaging
• Virtual Convex
• Patient information database
• Image Archive on integrated CD/DVD and Hard Drive
• Advanced 3D
• Raw Data Analysis
• Real-time automatic Doppler calcs
• OB Calcs
• Fetal Trending
• Multi gestational Calcs
• Hip Dysplasia Calcs
• Gynecological Calcs
• Vascular Calcs
• Urological Calcs
• Renal Calcs
• Cardiac Calcs
• inSite ExC Capability
• On-board electronic documentation

 

GE LOGIQ E9 with XDclear 2.0 Dimensions and Weight:
• Height: 51 in.
• Width: 23 in.
• Depth: 33.5 in.
• Weight: 297 lb

GE LOGIQ E9 with XDclear 2.0 Specifications:
• Digital Beamformer
• Imaging Depth: 0-36cm [Minimum: 0-2 cm (Zoom); Maximum: 0-36 cm]
• Continuous Dynamic Receive Focus/Continuous Dynamic Receive Aperture
• Adjustable Dynamic Range
• Adjustable Field of View [FOV]

GE LOGIQ E9 with XDclear 2.0 Console ports:
• DVI-I interface
• S-Video Output
• Wireless LAN
• Multiple USB 2.0 ports

GE LOGIQ E9 with XDclear 2.0 image storage:
• On-board database of patient information from past exams
• Storage formats:

-DICOM®-compressed or uncompressed, single/multi-frame, with/without raw data, storage via clipboard and/or seamlessly directly to destination device

-Transfer/“Save As” JPEG, MPEG, AVI formats

• Storage devices (optional ) :

-USB memory stick: eight GB

-CD-RW storage: 700 MB (DVD option required)

-DVD storage: -RW (4.7 GB)

-Hard drive image storage: one TB

• Compare previous images with current exam
• Reload of archived data sets
• Storage Format

-DICOM, Export JPEG, WMV(MPEG4), AVI

• Storage Devices

-USB Memory Stick (64MB to 64GB; CD-R Storage (700MB)

-DVD-R Storage (4.7GB)

-Hard Drive Image Storage (~335GB)

• On-Board database of patient information from past exams
• Compare previous exam images with current exam
• Reload of archived data sets


GE LOGIQ E9 with XDclear 2.0 Optional Features:
• LOGIQView
• Coded Contrast Imaging [not available in the US]
• B Flow (including B Flow Color)
• Volume Navigation
• Scan Assistant
• DICOM 3.0 connectivity
• Report Writer
• Real-Time 4D
• Physiological Input Panel
• Wireless LAN
• CW Doppler
• Tissue Velocity Imaging (TVI)
• Shear Wave and Strain Elastography
• TV Probe Holder
• Tomographic Ultrasound Imaging
• Volume Calculation (VOCAL II)
• Volume Contrast Imaging (VCI) Static
• Quantification (Elastography [not available in the US], Color Flow/PDI, Volume, TVI, Contrast)
• Stress Echo
• Auto IMT
• Compare Assistant
• Breast Productivity Package
• Thyroid Productivity Package
• OB Measure Assistant
• Breast Measure Assistant
• Tru3D
• Integrated Gel Warmer
• B Steer+
• Parametric Imaging
• Auto Ejection Fraction (Auto EF)
• Cardiac Automatic Function Imaging (Cardiac AFI)
• RF Data Capture

 

GE LOGIQ E9 with XDclear 2.0 Probes/Transducers:

Note: The GE Logiq E9 with XDclear 2.0 and the former version of Logiq E9 systems transducers are identical except for the C2-7-D, C2-7VN-D, C3-10-D, and L3-9i-D which are an incremental improvement from the exisiting transducers.


XDclear Convex Probes
C1-6-D [1-6MHz]
C1-6VN-D
C2-9-D [2-9MHz]
C2-9VN-D
C3-10-D [2-11MHz]

Convex Probe
M6C-D
C1-5-D [1-6MHz]
C2-6b-D [2-6MHz]
C2-7-D
C2-7VN-D

Intra-Cavitary Probe
IC5-9-D [3-10MHz]

Micro-Convex Probe
C2-7-D [1-6MHz]
C2-7VN-D
3CRF-D
3CRF

Linear Probe
9L-D [2-8MHz]
11L-D [3-11MHz]
ML6-15-D [4-15MHz]
L8-18i-D [4-15MHz]
L3-9i-D [2-19MHz]

Sector
S1-5-D [1-6MHz]
S1-5
M5S-D [1-5MHz]
6S-D [2-8MHz]
S4-10-D [3-9MHz]
S4-10

Real-time 4D
RAB6-D [2-8MHz]
RAB2-5-D
RAB4-8-D
RNA5-9-D
RIC5-90D[3-10MHz]
RSP6-16-D [6-18MHz]

Speciality
6Tc-RS [2-8MHz]
P2D [2MHz]
P6D [6.3MHz]

 

Last modified on Monday, 15 June 2020 16:36

 

Contact Us Online

or call 760-754-3288

REQUEST A QUOTE

UDS maintains a secure website   

Your connection to our website is secured with the latest SSL encryption technology. UDS will never share the information entered here with a third party without your express permission.

 UDS is registered with the FDA  

The Universal Diagnostic Solutions (UDS) warehouse and showroom facility located in Vista, California USA is registered with the Food and Drug Administration (FDA).

UDS is cbop approved  

UDS is approved by the California State Board of Pharmacy (CBOP) and legally authorized to sell class II medical devices. Learn more about UDS and how we can help you.